Danze D562040 - Installation Manual Manuel d'utilisateur Page 7

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 35
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 6
®
6
7.3
A.
B.
C.
Reinstall thermostatic handle assembly.
Turn off the volume control handle clockwise.
Reinstall temperature selector handle. The temperature
limit over-ride button should align the gun sight on limit
stop.
Install the screw in the thermostatic handle and
tighten it by hex wrench (supplied), then attach
the handle cap.
Over-ride button is in line with the gun sight.
7.2-C
Resetting Maximum Output Temperature of Valve
1) Turn off the volume control
2) Return the handle position to the High Temp Over-Ride Position.
3) Remove the Handle Assembly (Figure 7.1)
4) Rotate the cartridge stem clockwise by 1/8 of a turn.
5) Reinstall the Handle Assembly (Figure 7.3)
6) Check the valve maximum output temperature by following 7.2-B. If the temperature is still above your desired
temperature, repeat steps 1 through 5.
© 2008 Danze, Inc. All rights reserved.
Vue de la page 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 34 35

Commentaires sur ces manuels

Pas de commentaire